©2005 Mizu Ent. Inc.
Phone 866-364-9681 · Fax :FAX: · spapartsnet.com
10
Spa Side Receptacle
Aqua Set Style
Ground
Return
Hot Input
(Thermostat In)
Thermostat Out
Jets Indicator
Blower Indicator
Balboa Error Codes
pd = Power supply, unit running
on battery backup
OH = Sensors reading 112-118
degrees
Flo = Improper flow or pressure
Switch malfunction
Cool = Water temp 20 degrees
below set point
ICE = Potential freeze condition
has been detected
Sn1 = Hi-limit sensor malfunction
Sn3 = Temp sensor malfunction
ILOC = Interlock failure - possible
Pump or ozone spike.
Hurricane Error Codes
PS = Flow or pressure
Switch failure
SH = Shorted sensor
OP = Open sensor
LO = Temp below 60
degrees - freeze
HL = Temp above 118
degrees
Gecko Error Codes
FLO = Pressure switch failure,
switch open
FLC = Pressure switch failure
switch closed
Prr = Temp sensor failure
Prh = Hi-limit sensor failure
HL = Sensor measuring
119 degrees
FrE = possible freeze condition
detected
Sundance Error Codes
ILOC = Interlock failure
OH = Sensor indicates water
temp above acceptable limits
FLO = Pressure switch malfunction
Hold = Panel buttons pressed to
many times to quickly
HOT = PCB temperature above
acceptable limit - air blower on
ICE = freeze condition
PnL = Communication between PCB
and panel interrupted
Sn1 = Hi-limit sensor failure
Sn3 = Temperature sensor failure
---- = Watch dog - Potential damage to
spa equipment
Hercules Error Codes
OH = Spa temp exceeds
Acceptable limits
FLO = Flow problem
ICE = Freeze condition
detected
SN1 = hi-limit sensor failure
SN2 = temp sensor failure
Brett Error Codes
OH = Temp exceeds 118
degrees
Fr = Freeze condition - temp
below 40 degrees
FL = Pressure switch
failure
EO = Shorted temp sensor
E1 = Open temp sensor
E2 = Shorted hi-limit sensor
E3 = Open hi-limit sensor
E4 = Shorted flow switch
E7 = Improper electrical
connection
Vita Error Codes
HiLi = Water temp over
acceptable limit
BJ2P = Pump/Blower purge -
Normal condition
FP = Freeze protect - temp
temp under acceptable limit
SS=0;SS=S;LS=O;LS=S = Multiple
causes; Open sensors, bad
connection to panel,
Improper voltage, etc.
Spa Side Error Codes
Technical Services